Product Information
What Contaminants Do UV Sterilizers Remove?
There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%.
UV water sterilizer package & delivery
Package: Plywood Case
Delivery: 10-15 working days after advanced payment confirmed
Payment terms: TT, Western Union, L/C,Paypal
Shipping: Sea shipping or air shipping or Fedex or DHL
Product Parameters
MODEL | RATE FLOW | POWER | QUANTITY OF LAMP | MNPT THREAD OR FLANGE | SHELL SIZE | ||||
/ | / | / | Total power | Number | screw thread flange | Long | Wide | High | |
/ | M³/h | GPM | W | / | / | / | mm | mm | mm |
TN-ZWX75-1 | 1-5 | 4.4-22 | 75 | 1 | 2" | / | 900 | 89 | 199 |
TN-ZWX75--1-1 | 1-5 | 4.4-22 | 75 | 1 | / | DN50 | 900 | 89 | 309 |
TN-ZWX75-2 | 5-10 | 22-44 | 150 | 2 | 2" | / | 900 | 265 | 248 |
TN-ZWX75-2-1 | 5-10 | 22-44 | 150 | 2 | / | DN80 | 900 | 265 | 280 |
TN-ZWX75-3 | 10-15 | 44-66 | 225 | 3 | / | DN100 | 900 | 243 | 378 |
TN-ZWX75-4 | 15-20 | 66-88 | 300 | 4 | / | DN100 | 900 | 329 | 349 |
TN-ZWX75-5 | 20-30 | 88-132 | 375 | 5 | / | DN100 | 900 | 269 | 409 |
TN-ZWX75-6 | 30-40 | 132-176 | 450 | 6 | / | DN150 | 900 | 389 | 439 |
TN-ZWX75-8 | 50-60 | 220-264 | 600 | 8 | / | DN150 | 900 | 423 | 493 |
TN-ZWX75-10 | 60-70 | 264-308 | 750 | 10 | / | DN150 | 900 | 423 | 493 |
TN-ZWX75-12 | 70-80 | 308-352 | 900 | 12 | / | DN150 | 900 | 423 | 493 |
TN-ZWX100-3 | 15-20 | 66-88 | 300 | 3 | / | DN100 | 1200 | 243 | 378 |
TN-ZWX100-4 | 20-30 | 88-132 | 400 | 4 | / | DN100 | 1200 | 379 | 409 |
TN-ZWX100-6 | 50-60 | 220-264 | 600 | 6 | / | DN150 | 1200 | 389 | 445 |
TN-ZWX100-8 | 60-70 | 264-308 | 800 | 8 | / | DN150 | 1200 | 528 | 403 |
TN-ZWX100-10 | 80-90 | 352-396 | 1000 | 10 | / | DN200(PN10) | 1200 | 423 | 528 |
TN-ZWX100-12 | 100-110 | 440-484 | 1200 | 12 | / | DN200(PN10) | 1200 | 438 | 513 |
TN-ZWX100-14 | 110-120 | 484-528 | 1400 | 14 | / | DN200(PN10) | 1200 | 468 | 533 |
TN-ZWX100-16 | 120-140 | 528-616 | 1600 | 16 | / | DN200(PN16) | 1200 | 438 | 543 |
TN-ZWX100-18 | 150-160 | 660-704 | 1800 | 18 | / | DN200(PN16) | 1200 | 438 | 553 |
TN-ZWX100-20 | 160-180 | 700-800 | 2000 | 20 | / | DN200(PN16) | 1200 | 325 | 565 |
Product Details
All kinds of the sterilization equipment are installed the high quality UV lamp.
304 or 316L stainless steel for the shell.
Stress tolerance of the shell:0.7Mpa.
The size of the shell is the standard size,customized the size of shell also is okay.
Customized the input and output of the pipe follow client's requirement.
All the equipment is installed the high quality ballast and it has the alarm and flashlight function to show situation of the UV light.